Zoom 508 User Manual

Browse online or download User Manual for Hardware Zoom 508. Zoom 508 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 6
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Thank you for selecting the ZOOM 508 (hereafter simply called the "508").
Please take the time to read this manual carefully so you can get the most out of
your 508 and ensure optimum performance and reliability.
Retain this manual for future reference.
ZOOM CORPORATION
NOAH Bldg., 2-10-2, Miyanishi-cho, Fuchu-shi, Tokyo 183, Japan
PHONE: 0423-69-7116 FAX: 0423-69-7115
Printed in Japan 508-5000
Compact, dedicated delay unit with up to 4000 ms delay time and eight delay
types (Four types x two variations).
On-board "Zfx-2" DSP (Digital Signal Processor) developed by Zoom, and
an innovative design used solely for its delay effects. Achieves superior
quality delay sound on a par with high-end devices.
You can switch between 24 patches to store diverse settings based on your
preference.
Seamless function that enables smooth patch transitions without cutting the
delay sound when the patch is switched.
Ample functions to support powerful live performances, including a hold
function for continuing the delay sound until the foot switch is pressed, and a
tap function for setting the delay time in the interval between when the foot
switch is pressed.
Integrated auto-chromatic tuner for guitar. You can tune your insturment
easily anywhere, any time. You can also leave the tuning function disabled all
the time.
The optional FP01 expression pedal enables foot control of the mix level for
the delay sound.
Dual power supply design allows the unit to be powered from an alkaline
battery (6LR61) or an AC adapter.
USAGE AND SAFETY PRECAUTIONS
In this manual, symbols are used to highlight warnings and
cautions for you to read so that accidents can be prevented. The
meanings of these symbols are as follows:
Please observe the following safety tips and precautions to ensure
hazard-free use of the 508.
Since power consumption of this unit is fairly high, we
recommend the use of an AC adapter whenever possible.
When powering the unit from a battery, use only an alkaline
type.
AC adapter operation
Be sure to use only an AC adapter which supplies 9 V DC,
300 mA and is equipped with a "center minus" plug (Zoom
AD-0006). The use of an adapter other than the specified type
may damage the unit and pose a safety hazard.
Connect the AC adapter only to an AC outlet that supplies the
rated voltage required by the adapter.
When disconnecting the AC adapter from the AC outlet,
always grasp the adapter itself and do not pull the cable.
If the unit is not to be used for a long time, disconnect the AC
adapter from the outlet.
Battery operation
Use only a 9 V (alkaline) battery (6LR61).
The 508 cannot be used for recharging.
Pay close attention to the labelling of the battery to make sure
you choose the correct type.
If the 508 is not to be used for an extended period of time,
remove the battery from the unit.
If battery leakage has occurred, wipe the battery compartment
and the battery terminals carefully to remove all remnants of
battery fluid.
While using the unit, the battery compartment cover should
be closed.
Avoid using your 508 in environments where it will be
exposed to:
Extreme temperature
High humidity or moisture
Excessive dust or sand
Excessive vibration or shock
The 508 is a precision instrument. Except for the foot
switches, do not push other parts with your feet or subject
them to strong force.
Take care that no foreign objects (coins or pins etc.) or liquids
enter the unit.
Be sure to turn the power to all equipment off before making
connections.
Before moving the unit, turn the power off and disconnect all
cables and the AC adapter.
Never open the case of the 508 or attempt to modify the
product in any way since this can result in damage to the unit.
Usage precautions
For safety considerations, the 508 has been designed to provide
maximum protection against the emission of electromagnetic
radiation from inside the device, and from external
interference.However, equipment that is very susceptible to
interference or that emits powerful electromagnetic waves
should not be placed near the 508, as the possibility of
interference cannot be ruled out entirely.
Whatever the type of digital control device, the 508 included,
electromagnetic damage can cause malfunctioning and corrupt
or destroy data. Since this is an ever-present danger, thorough
care should be taken to minimize the risk of damage.
Use a soft, dry cloth to clean the 508. If necessary, slightly
moisten the cloth. Do not use abrasive cleanser, wax, or
solvents (such as paint thinner or cleaning alcohol), since these
may dull the finish or damage the surface.
Connecting cables and input and output jacks
You should always turn off the power to the 508 and all other
equipment before connecting or disconnecting any cables. Also
make sure to disconnect all cables and the AC adapter before
moving the 508.
Major Features
Safety Precautions
Warning
This symbol indicates explanations about extremely
dangerous issues. If users ignore this symbol and handle
the device incorrectly, serious injury or death could
result.
Caution
This symbol indicates explanations about dangerous
issues. If users ignore this symbol and handle the
device the wrong way, bodily injury and damage to the
equipment could result.
Warning
About power
Caution
Environment
Caution
Handling
Caution
Alterations
Electrical interference
Cleaning
1
2
Operation Manual
Page view 0
1 2 3 4 5 6

Summary of Contents

Page 1 - Safety Precautions

Thank you for selecting the ZOOM 508 (hereafter simply called the "508"). Please take the time to read this manual carefully so you can get

Page 2 - Rear Panel

• PATCH A group of the settings for a certain effect type is called a PATCH. The 508 comes with 24 presetpatches which can be changed (edited) by the

Page 3 - Using the Bypass/Tuner Mode

The 24 patches can be easily selected bypressing the patch pedals. The right patchpedal switches to the next patch and theleft patch pedal switches to

Page 4 - Patch switching

In the initial setting, the patchpedal switches all patches inorder, regardless of the bankdivisions.The bank hold function limitsswitching to the fou

Page 5 - Effect Parameters

The 508 comes with 24 predefined patches. However, the 508 offers many more possibilities forcombining effects in innovative ways. To discover these p

Page 6 - 6LR61 9 V (alkaline) battery

If you have edited (altered) a patch and turn the 508 off without storing the patch, the patch willrevert to its old setting. To store an edited patch

Comments to this Manuals

No comments